Standards and Classifications

Created by the European Committee for Standardization, the European Standard EN 13123/124-1 and EN 13123/124-2 are internationally recognized standards used to qualify the protection provided of security structures and products (complete with fillings and locks). To receive certification, products are independently tested on sites with companies such as Comblast in highly regulated environments to provide the level of protection requested. Safetell products have also been tested to ISO 16933.

Please see the blast ratings below. Ratings are to the actual need, i.e. 5 tons/m2 of 180 milliseconds (ms) and to an equivalent of 100kg of TNT at a given distance

Blast Resistant Classifications EN13123-1 Shock Tube Test (Doors, Windows, Shutters)

Classification EPR1 (Splinters / No Splinters)

Peak Pressure (bar): 0.5

Positive specific impulse I + (bar-ms): 3.7

Duration (ms): >20

Classification EPR2 (Splinters / No Splinters)

Peak Pressure (bar): 1

Positive specific impulse I + (bar-ms): 9

Duration (ms): >20

Classification EPR3 (Splinters / No Splinters)

Peak Pressure (bar): 1.5

Positive specific impulse I + (bar-ms): 15

Duration (ms): >20

Classification EPR4 (Splinters / No Splinters)

Peak Pressure (bar): 2

Positive specific impulse I + (bar-ms): 22

Duration (ms): >20

Blast Resistant Classifications EN13123-2 Range Test (Doors, Windows, Shutters)

Classification EXR1 (Splinters / No Splinters)

Mass of TNT explosive charge (kg): 3

Distance: 5m

Classification EXR2 (Splinters / No Splinters)

Mass of TNT explosive charge (kg): 3

Distance: 3m

Classification EXR3 (Splinters / No Splinters)

Mass of TNT explosive charge (kg): 12

Distance: 5.5m

Classification EXR4 (Splinters / No Splinters)

Mass of TNT explosive charge (kg): 12

Distance: 4m

Classification EXR5 (Splinters / No Splinters)

Mass of TNT explosive charge (kg): 20

Distance: 4m